Chapter 7 Troubleshooting Virtualization Engine Devices 73
For Internal Use Only
Power LED Codes
The virtualization engine LEDs are shown in FIGURE 7-1.
FIGURE 7-1 Virtualization Engine Front Panel LEDs
Interpreting LED Service and Diagnostic Codes
The Status LED communicates the status of the virtualization engine in decimal
numbers. Each decimal number is represented by number of blinks, followed by a
medium duration (two seconds) of LED off.
TABLE 7-2 lists the status LED code
descriptions.
The blink code repeats continuously, with a four-second off interval between code
sequences.
TABLE 7-2 LED Service and Diagnostic Codes
0 Fast blink
1 LED blinks once
2 LED blinks twice with one short duration (one second) between blinks
3 LED blinks three times with one short duration (one second) between blinks
...
10 LED blinks ten times with one short duration (one second) between blinks