Sun-microsystems StorEdge 6900 Series Manuel d'utilisateur Page 81

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 162
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 80
Chapter 6 Troubleshooting Sun StorEdge FC Switch-8 and Switch-16 Devices 65
For Internal Use Only
switch enclosure Audit Auditing a new
switch called ras
d2-swb1
(ip=xxx.0.0.41)
10002000007a609
switch oob Comm_
Established
Communication
regained with
sw1a
(ip=xxx.20.67.213)
switch oob Comm_Lost Down Yes [ Info/Action ] Lost
communication with
sw1a
(ip=xxx.20.67.213)
Information:
Ethernet
connectivity to the
switch has been lost.
Recommended
action:
1. Check Ethernet
connectivity to
the switch.
2. Verify that the
switch is booted
correctly with no
POST errors.
3. Verify that the
switchTest Mode
is set for normal
operations.
4. Verify the TCP/
IP settings on
switchvia Forced
PROM Mode
access.
5. Replace switch, if
needed.
switch switchtest Diagnostic
Test-
Red switchtest (diag240)
on d2-swb1
(ip=xxx.0.0.41)
10002000007a609
TABLE 6-1 Storage Automated Diagnostic Environment Event Grid for Switches (Continued)
Cat Component EventType Sev Action Description Information/Action
Vue de la page 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 161 162

Commentaires sur ces manuels

Pas de commentaire