Chapter 7 Troubleshooting Virtualization Engine Devices 71
For Internal Use Only
To Display Log Files and Retrieve SRNs
Use the /opt/svengine/sduc/sreadlog command to display log files and
retrieve the Service Request Numbers (SRN) for errors that need action. Data is
returned in the following format:
TimeStamp:nnn:Txxxxx.uuuuuuuu SRN=mmmmm
TimeStamp:nnn:Txxxxx.uuuuuuuu SRN=mmmmm
TimeStamp:nnn:Txxxxx.uuuuuuuu SRN=mmmmm
Example
Item Description
TimeStamp Time and date when error occurred
nnn The name of the virtualization engine pair (v1 or v2)
Txxxxx The LUN where the error occurred.
Note: Txxxxx can represent a physical or a logical LUN.
uuuuuuuu The unique ID of the drive or the virtualization engine router
SRN=mmmmm The SRN defined in numerical order
# /opt/svengine/sduc/sreadlog -d v1
2002:Jan:3:10:13:05:v1.29000060-220041F9.SRN=70030
2002:Jan:3:10:13:31:v1.29000060-220041F9.SRN=70030
2002:Jan:3:10:17:10:v1.29000060-220041F9.SRN=70030
2002:Jan:3:10:17:37:v1.29000060-220041F9.SRN=70030
2002:Jan:3:10:22:26:v1.29000060-220041F9.SRN=70030
2002:Jan:3:10:25:54:v1.29000060-220041F9.SRN=70030
Vue de la page 86