Appendix B SUNWsecfg Error Messages 139
restoret3config Error while the block size compare
command is executing. The
$BRICK_IP{$IPADD} command is
aborted.
The Sun StorEdge T3+ array block size
parameter is different from the
snapshot file. The Sun StorEdge T3+
array may have been reconfigured.
Run restoret3config.
restoret3config $LUN configuration failed to restore
and the force option was used to
reinitialize, without success
Check the Sun StorEdge T3+
configuration with the showt3 -n
t3_name command. Restore the Sun
StorEdge T3+ array configuration with
the restoret3config command.
restoret3config $LUN configuration is not found in the
$restore_file. Cannot restore
$LUN.
Check for snapshot files in the
/opt/SUNWsecfg/etc/t3_name/
directory. If the snapshot files are not
found, use the modifyt3config
command to configure the Sun
StorEdge T3+ array.
savet3config While checking the configuration, the
Sun StorEdge T3+ array configuration
has not been saved.
Check the Sun StorEdge T3+ array
configurationby usingthe showt3 -n
t3_name command, if the
configuration is different from
standard Sun StorEdge T3
configurations. Use the
modifyt3config command to
reconfigure the device.
TABLE B-3 Sun StorEdge T3+ Array SUNWsecfg Error Messages (Continued)
Message Description and Cause of Error Suggested Action
Vue de la page 154

Commentaires sur ces manuels

Pas de commentaire

Powermate 024-0077CT Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Elektrische Schraubenschlüssel Powermate 024-0077CT.
Wir stellen 1 PDF-Handbücher Powermate 024-0077CT zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Bedienungsanleitung






Weitere Produkte und Handbücher für Elektrische Schraubenschlüssel Powermate

Modelle Dokumententyp
Keine