Sun-microsystems StorEdge 6900 Series Manuel d'utilisateur Page 44

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 162
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 43
28 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
To Isolate the A1/B1 FC Link
1. Quiesce the I/O on the A1/B1 FC link path.
2. Run switchtest or qlctest to test the entire link.
3. Break the connection by uncabling the link.
4. Insert a loopback connector into the switch port.
5. Rerun switchtest.
a. If switchtest fails, replace the GBIC and rerun switchtest.
b. If switchtest fails again, replace the switch.
6. Insert a loopback connector into the HBA.
7. Run qlctest.
If the test fails, replace the HBA.
If the test passes, replace the cable.
8. Recable the entire link.
9. Run switchtest or qlctest to validate the fix.
10. Return the path to production.
Vue de la page 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 161 162

Commentaires sur ces manuels

Pas de commentaire