Sun-microsystems X4150 Manuel d'utilisateur Page 62

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 82
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 61
52 Sun Fire X4150 Server Installation Guide May 2009
RAID Drive Options
TABLE 4-3 shows the RAID drive options:
TABLE 4-3 RAID Drive Options
SAS Card Drives Suppor ted RAID Configuration Supported Drive Usage
Sun
StorageT
ek
Seagate 7 3GB SAS Volume 1 disk
Fujitsu 73 GB SAS RAID 0 stripe 2 disk
minimum
No redundancy
Hitachi 146 GB SAS RAID 1 mirror 2 disk
minimum
50%
RAID 1E 3 drive minimum 50%
RAID 10 4 drive minimum 50%
RAID 5 3 drive minimum 67–94%
RAID 5EE 4 drive minimum 50–88%
RAID 50 6 drive minimum 67–94%
RAID 6 4 drive minimum 50–88%
RAID 60 8 drive minimum 50–88%
Spanned Volume 2 drive
minimum
100%
RAID Volume 4 drive
minimum
50-100%
LSI
3081E
Seagate 73 GB SAS IM Integrated Mirror array. 2
disk minimum, plus up to 2 hot
spare disks.
Data on Primary disk might be
merged.
Fujitsu 73GB SAS IME Integrated Mirror
Enhanced array. 3 to 8 disks
including up to 2 hot spares.
All data will be deleted during
creation.
Hitachi 146 GB SAS IS – Integrated Striping array. 2
to 8 disks.
All data will be deleted during
creation.
Vue de la page 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 81 82

Commentaires sur ces manuels

Pas de commentaire