Sun Fire
X2250 Server
Service Manual
Part No. 820-4593-12, Rev. A
February 2010
Vue de la page 0
1 2 3 4 5 6 ... 133 134

Résumé du contenu

Page 1 - Service Manual

Sun Microsystems, Inc.www.sun.comSubmit comments about this document by clicking the Feedback[+] link at: http://docs.sun.comSun Fire™X2250 ServerServ

Page 2

x Sun Fire X2250 Server Service Manual • April 2009Typographic ConventionsRelated DocumentationTo view a list of documents that are available for the

Page 3 - Contents

A-2 Sun Fire X2250 Server Service Manual • April 2009A.2 Power SpecificationsMaximum continuous power is 500 W. Other specifications are shown in thef

Page 4

Appendix A System Specifications A-3A.3 Environmental SpecificationsEnvironmental specifications for the Sun Fire X2250 server are shown in TABLE A-6.

Page 5 - Contents v

A-4 Sun Fire X2250 Server Service Manual • April 2009A.4 Serial Connector Pin AssignmentsThe serial management port connector is an RS-232-F RJ-45 typ

Page 6

B-1APPENDIXBUsing the Tools & Drivers CDThis chapter contains information about the Sun Fire X2250 Server Tools & DriverCD. It contains inform

Page 7 - Contents vii

B-2 Sun Fire X2250 Server Service Manual • April 2009B.2 Updating BIOSYou can update the BIOS from the Tools & Drivers CD using the local X2250 se

Page 8 - Index Index–1

Appendix B Using the Tools & Drivers CD B-3B.2.2 Updating Sun Fire X2250 BIOS From a RemoteClientThe following requirement must be met prior to up

Page 9 - How This Book Is Organized

B-4 Sun Fire X2250 Server Service Manual • April 2009B.3 Updating SP FirmwareYou can update the SP firmware from the Tools & Drivers CD using one

Page 10 - Typographic Conventions

Appendix B Using the Tools & Drivers CD B-53. Ensure that the OS on the platform is shut down.4. Log in to the Sun Fire X2250 ILOM CLI with Admini

Page 11 - Third-Party Web Sites

B-6 Sun Fire X2250 Server Service Manual • April 20095. Select Maintenance --> Firmware Upgrade tabs.The Firmware Upgrade page appears.6. Click Ent

Page 12 - Sun Welcomes Your Comments

Appendix B Using the Tools & Drivers CD B-7B.4 Booting the Tools & Drivers CD From aPXE ServerIf you have a Sun Fire X2250 server that does no

Page 13

Preface xiSupport and TrainingProduct UpdatesFor product updates that you can download for the Sun Fire X2250 server, pleasevisit the following web si

Page 14 - 1.1 Features

B-8 Sun Fire X2250 Server Service Manual • April 2009The default directory for the PXE image is usually /tftpboot/linux-install.The remainder of this

Page 15 - 1.2.1 Preinstalled Software

Appendix B Using the Tools & Drivers CD B-99. Edit the Boot Message Screen as follows.a. Open the boot.msg file in a text editor.b. Type the follo

Page 16 - 1.3 Hardware System Overview

B-10 Sun Fire X2250 Server Service Manual • April 2009B.4.2 Accessing the Tools & Drivers CD From the TargetSun Fire X2250 ServerYou will need the

Page 17 - 1.3.2 Internal Components

Appendix B Using the Tools & Drivers CD B-11B.5 Intel PROSET Driver SoftwareIncluded on the Tools & Drivers CD is a driver software package fo

Page 18

B-12 Sun Fire X2250 Server Service Manual • April 20092. Locate the Product Part Number (PPN) from the CIS sheet (or from either ILOMor sdfru -l befor

Page 19 - Processor Configuration

C-1APPENDIXCInstalling the Server Into a RackWith Optional Slide RailsPerform the procedures in this chapter to install your server into a four-post r

Page 20 - FIGURE 1-1

C-2 Sun Fire X2250 Server Service Manual • April 2009C.1 Disassembling the Slide Rails BeforeInstallationUse this procedure to remove the mounting bra

Page 21 - 1.4.4 Clearing the CMOS

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-3C.2 Installing the Mounting Brackets Ontothe ServerUse this procedure to ins

Page 22

C-4 Sun Fire X2250 Server Service Manual • April 20094. Repeat Steps 1 through 3 to install the remaining mounting bracket on the otherside of the ser

Page 23 - Troubleshooting

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-5FIGURE C-3 Slide-Rail Assembly Mounting to Rack Post3. Repeat Step 1 and Ste

Page 24 - 2.1 Troubleshooting Overview

xii Sun Fire X2250 Server Service Manual • April 2009WarrantyFor specific details regarding your warranty, visit:http://www.sun.com/service/support/wa

Page 25 - Chapter 2 Troubleshooting 2-3

C-6 Sun Fire X2250 Server Service Manual • April 2009FIGURE C-4 Setting the Rail Width5. Tighten the screws on the brackets.6. Remove the spacer and c

Page 26 - Troubleshooting Procedures

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-78. If available, extend the anti-tilt bar at the bottom of the rack. (See FI

Page 27 - Chapter 2 Troubleshooting 2-5

C-8 Sun Fire X2250 Server Service Manual • April 20091. Push the slide rails into the slide-rail assemblies in the rack as far as possible.2. Raise th

Page 28 - Problem Possible solution

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-9Caution – Verify that the server is securely mounted in the rack and that th

Page 29 - Chapter 2 Troubleshooting 2-7

C-10 Sun Fire X2250 Server Service Manual • April 2009FIGURE C-7 Inserting the CMA Rail Extension Into the Back of the Left Slide RailCMA railextensio

Page 30

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-114. Verify that the CMA rail extension engages the slide rail, as shown inFI

Page 31 - Performing Diagnostics

C-12 Sun Fire X2250 Server Service Manual • April 20095. Insert the CMA’s mounting bracket connector into the right slide rail until theconnector lock

Page 32

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-136. Insert the right CMA slide-rail connector into the right slide-rail asse

Page 33 - Option Description

C-14 Sun Fire X2250 Server Service Manual • April 20097. Insert the left CMA slide-rail connector into the rail extension on the left slide-rail assem

Page 34 - Diagnostics Tests menu

Appendix C Installing the Server Into a Rack With Optional Slide Rails C-158. Position the cable hangers in the appropriate mounting holes in the CMA

Page 35

1-1CHAPTER1Sun Fire X2250 Server OverviewThis chapter provides an overview of the Sun Fire X2250 server, as well as power-onand power-off procedures a

Page 36 - 3.3.1 Testing the Hard Disk

C-16 Sun Fire X2250 Server Service Manual • April 2009C.6 Verifying Operation of the Slide Railsand CMAUse this procedure to ensure that the slide rai

Page 37 - 3.4 Immediate Burn-in Testing

Index-1IndexAair ductlocation, 1-6, 4-5replacing, 4-20altitude specifications, A-3Bbatterylocation, 1-6, 4-5replacing, 4-33BIOS firmwareCD, 1-4updating

Page 38

Index-2 Sun Fire X2250 Server Service Manual • February 2010diagnostics CD, 1-4DIMMs, see memory modulesdriver updates, -xidual blower modulereplacing

Page 39 - 3.5 Deferred Burn-in Testing

Index-3physical specifications, A-1postinstallation instructions, 4-3Power button, 1-5power connector, 1-5power LED, 1-5power problemstroubleshooting,

Page 40

Index-4 Sun Fire X2250 Server Service Manual • February 2010Tools and Drivers CDdescription, 1-4tools for maintenance procedures, 4-1troubleshooting,

Page 41

1-2 Sun Fire X2250 Server Service Manual • April 20091.1 FeaturesTABLE 1-1 lists the system’s key components.1.2 Operating System and SoftwareThis sec

Page 42 - ■ Select Yes and press Enter

Chapter 1 Sun Fire X2250 Server Overview 1-31.2.1 Preinstalled SoftwareIf you ordered a hard drive with your Sun Fire X2250 server, the hard drive mig

Page 43

1-4 Sun Fire X2250 Server Service Manual • April 20091.2.3 Tools & Drivers CD SoftwareThe Sun Fire X2250 server Tools & Drivers CD, which is a

Page 44

Chapter 1 Sun Fire X2250 Server Overview 1-5FIGURE 1-2 shows the back panel of the Sun Fire X2250 server.FIGURE 1-2 Back Panel1.3.2 Internal Component

Page 45 - Solaris 10 Operating System

1-6 Sun Fire X2250 Server Service Manual • April 2009FIGURE 1-3 Sun Fire X2250 Server System ComponentsTABLE 1-4 Sun Fire X2250 Server Internal Compon

Page 46 - 3.7 Show Results Summary

Chapter 1 Sun Fire X2250 Server Overview 1-71.4 Powering On and Powering Off theServerYou only need to apply standby power to the server at this point

Page 47

PleaseRecycleCopyright © 2010 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.Sun Microsystems,

Page 48 - 3.10 Exit to DOS

1-8 Sun Fire X2250 Server Service Manual • April 20091.4.2 Powering On Main Power ModeTo power on main power for all server components:1. Verify that

Page 49 - 4.1 Tools and Supplies Needed

Chapter 1 Sun Fire X2250 Server Overview 1-91.4.4 Clearing the CMOSYou can use this procedure to clear the server's CMOS settings in the case of

Page 50 - 4.2 Installation Precautions

1-10 Sun Fire X2250 Server Service Manual • April 2009

Page 51 - FIGURE 1-2)

2-1CHAPTER2TroubleshootingThis chapter contains information on troubleshooting procedures and technicalsupport contacts.The following sections are inc

Page 52 - Removing the Server Cover

2-2 Sun Fire X2250 Server Service Manual • April 20092.1 Troubleshooting OverviewBefore troubleshooting your specific server problem, answer the follo

Page 53 - 5 DIMM slots (4) 13 I/O board

Chapter 2 Troubleshooting 2-32.2.1 Performing an External Visual Inspection1. Turn off the system and any attached peripherals (if applicable).2. Veri

Page 54

2-4 Sun Fire X2250 Server Service Manual • April 20092.3 Troubleshooting ProceduresTABLE 2-1 lists problems that might arise as you use your server. P

Page 55 - 4.5.1 Replacing the I/O Board

Chapter 2 Troubleshooting 2-5System cannot readthe hard diskinformation.Do the following:1. Turn off the server by pressing the Power button.2. Remove

Page 56 - Installing the I/O Board

2-6 Sun Fire X2250 Server Service Manual • April 2009No video is displayedon the monitorscreen.Check the following:• Is the monitor cable connected to

Page 57 - 35W cards

Chapter 2 Troubleshooting 2-72.4 Getting Technical AssistanceIf the troubleshooting procedures in this chapter fail to solve your problem, seeTABLE 2-

Page 58 - FIGURE 4-7

iiiContentsPreface ix1. Sun Fire X2250 Server Overview 1–11.1 Features 1–21.2 Operating System and Software 1–21.2.1 Preinstalled Software 1–31.2.2 Su

Page 59 - Removing a PCIe Card

2-8 Sun Fire X2250 Server Service Manual • April 2009

Page 60 - Installing the PCIe Card

3-1CHAPTER3Performing DiagnosticsThis chapter assists you with using the Diagnostics application on the Sun Fire X2250Server Tools & Drivers CD. T

Page 61 - Removing a Hard Disk Drive

3-2 Sun Fire X2250 Server Service Manual • April 20093.1 Pc-Check Diagnostics OverviewSun Fire X2250 server diagnostics are contained in the DOS-based

Page 62 - Installing a Hard Disk Drive

Chapter 3 Performing Diagnostics 3-3To run a specific hardware component test, select Advanced Diagnostics Test.Torunone of the test scripts supplied

Page 63

3-4 Sun Fire X2250 Server Service Manual • April 20093.3 Advanced Diagnostics Tests MenuOptionsTABLE 3-2 gives the name and a brief description of eac

Page 64

Chapter 3 Performing Diagnostics 3-5Diskettes Not applicable for the Sun Fire X2250 server.Hard Disks Details information about the hard disk, and inc

Page 65 - Carrier” on page 4-14

3-6 Sun Fire X2250 Server Service Manual • April 20093.3.1 Testing the Hard Disk1. From the main menu, choose Advanced Diagnostics Tests.2. From the A

Page 66

Chapter 3 Performing Diagnostics 3-7 Device Test SettingsEnables you to select the test time durations of the devices and the test level. Number of

Page 67 - Removing the ODD Filler Panel

3-8 Sun Fire X2250 Server Service Manual • April 2009When you select the Immediate Burn-in Testing menu option, the ContinuousBurn-in Testing window i

Page 68 - 4.5.6 Replacing the Air Duct

Chapter 3 Performing Diagnostics 3-91. From the main menu, choose Immediate Burn-in Testing.The top portion of the window lists the options described

Page 69 - , aligning the baffle

iv Sun Fire X2250 Server Service Manual • February 20102.1 Troubleshooting Overview 2–22.2 Performing Visual Inspections 2–22.2.1 Performing an Extern

Page 70 - Installing the Air Duct

3-10 Sun Fire X2250 Server Service Manual • April 20092. Complete one of the following options: Load Burn-in ScriptEnter one of the following: quick

Page 71 - Removing the Power Supply

Chapter 3 Performing Diagnostics 3-11 Section 3.6.3, “Creating a Log File on the Diagnostic Partition” on page 3-12 Section 3.6.4, “Accessing the Di

Page 72 - Installing the Power Supply

3-12 Sun Fire X2250 Server Service Manual • April 20099. Type Y to erase the data and the partition.10. Repeat Step 6 through Step 9 until all partiti

Page 73 - Removing the Fan Module

Chapter 3 Performing Diagnostics 3-13The following procedure shows an example of how to create and access a log file onthe diagnostic partition for th

Page 74 - Installing the Fan Module

3-14 Sun Fire X2250 Server Service Manual • April 20094. Determine if your diagnostic partition has been configured to be mounted bytyping the followi

Page 75

Chapter 3 Performing Diagnostics 3-153.6.5 Accessing the Diagnostic Partition on theSolaris 10 Operating SystemTo access the diagnostic partition on t

Page 76

3-16 Sun Fire X2250 Server Service Manual • April 20093.6.6 Accessing the Diagnostic Partition on theWindows Server 2003 Operating SystemThe Windows 2

Page 77 - 4.5.10.2 Removing a DIMM

Chapter 3 Performing Diagnostics 3-17 MotherboardThis section shows the following tests conducted against the motherboard:DMA Controller Tests, Syste

Page 78 - Bank 1 DIMM Slot Locations

3-18 Sun Fire X2250 Server Service Manual • April 20093.8 Print Results ReportThe Print Results Report option enables you to print system diagnostic r

Page 79 - 4.5.10.3 Installing a DIMM

4-1CHAPTER4Maintaining the Sun Fire X2250ServerThis chapter describes how to add, replace, and configure components in the SunFire X2250 server after

Page 80 - Installing a DIMM

Contents v3.10 Exit to DOS 3–184. Maintaining the Sun Fire X2250 Server 4–14.1 Tools and Supplies Needed 4–14.2 Installation Precautions 4–24.2.1 ESD

Page 81 - FIGURE 4-30 for the

4-2 Sun Fire X2250 Server Service Manual • April 2009 Alcohol pads (for CPU replacement by service personnel only) 5 mm nut driver (for motherboard

Page 82 - Removing the System Battery

Chapter 4 Maintaining the Sun Fire X2250 Server 4-32. Remove the server cover.See Section 4.3, “Powering Off the Server and Removing the Cover” on pag

Page 83 - Installing the System Battery

4-4 Sun Fire X2250 Server Service Manual • April 20094. Label and disconnect all peripheral cables and all telecommunication linesconnected to I/O con

Page 84 - FIGURE 4-32)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-54.4 Locations of Server ComponentsFIGURE 4-2 Sun Fire X2250 Server System ComponentsTABLE 4-1 Sun F

Page 85 - Removing a Heatsink

4-6 Sun Fire X2250 Server Service Manual • April 20094.5 Component Replacement ProceduresThe following components are customer-replaceable units (CRUs

Page 86 - Removing the CPU

Chapter 4 Maintaining the Sun Fire X2250 Server 4-74.5.1 Replacing the I/O BoardThe following procedures describe how to remove and replace an I/O boa

Page 87 - Installing the CPU

4-8 Sun Fire X2250 Server Service Manual • April 20094.5.1.2 Installing the I/O BoardTo install the I/O board:1. Position the I/O board on top of the

Page 88 - FIGURE 4-35

Chapter 4 Maintaining the Sun Fire X2250 Server 4-94.5.2 Replacing the PCIe Card and Riser AssemblyNote – Many of the illustrations in this section sh

Page 89 - 4.5.13 Installing a New CPU

4-10 Sun Fire X2250 Server Service Manual • April 2009Note – The examples shown in these procedures use the x8 card, but the installationand removal i

Page 90

Chapter 4 Maintaining the Sun Fire X2250 Server 4-11FIGURE 4-7 Removing a PCIe Card4.5.2.2 Installing the PCIe Card and Riser Card AssemblyTo install

Page 91 - Installing the Heatsink

vi Sun Fire X2250 Server Service Manual • February 20104.5.7 Replacing the Power Supply 4–224.5.7.1 Removing the Power Supply 4–224.5.7.2 Installing t

Page 92 - 4.5.14 Replacing Cables

4-12 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-9 Installing the PCIe Card3. Reinstall the riser assembly into the connector on the mot

Page 93 - 4.5.15 Motherboard

Chapter 4 Maintaining the Sun Fire X2250 Server 4-134. Check the routing of all cables for obstructions, and then reinstall the cover asdescribed in S

Page 94 - Removing the Motherboard

4-14 Sun Fire X2250 Server Service Manual • April 20093. Grasp the carrier bezel with both hands and carefully pull the carrier out of thedrive bay.No

Page 95 - Installing the Motherboard

Chapter 4 Maintaining the Sun Fire X2250 Server 4-154.5.4 Replacing an HDD Backplane AssemblyThe following procedure describes how to replace the hard

Page 96 - 7. Replace the system cover

4-16 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-13 Removing the HDD Backplane Assembly4.5.4.2 Replacing an HDD BackplaneTo install the

Page 97

Chapter 4 Maintaining the Sun Fire X2250 Server 4-17FIGURE 4-14 Replacing the HDD Backplane Assembly5. Reinsert the HDD as described in Section 4.5.3.

Page 98

4-18 Sun Fire X2250 Server Service Manual • April 20094.5.5 Removing and Installing the ODD DriveAssemblyThe following procedure describes how to repl

Page 99 - System Specifications

Chapter 4 Maintaining the Sun Fire X2250 Server 4-194. Pull the ODD drive out the front of the chassis.Caution – Move the assembly by grasping it by i

Page 100 - A.2 Power Specifications

4-20 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-17 Installing the ODD Assembly4. Reinstall the ODD drive cable.5. Check the routing of

Page 101 - TABLE A-6

Chapter 4 Maintaining the Sun Fire X2250 Server 4-21FIGURE 4-18 Removing the Air Duct4.5.6.2 Installing the Air DuctTo install the air duct:1. Positio

Page 102

Contents viiA.4 Serial Connector Pin Assignments A–4B. Using the Tools & Drivers CD B–1B.1 Tools & Drivers CD Contents B–1B.2 Updating BIOS B–

Page 103

4-22 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-19 Installing the Air Duct4.5.7 Replacing the Power SupplyThe following procedures desc

Page 104 - B.2 Updating BIOS

Chapter 4 Maintaining the Sun Fire X2250 Server 4-23FIGURE 4-20 Removing the Power Supply6. Lift the power supply out of the chassis.4.5.7.2 Installin

Page 105

4-24 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-21 Installing the Power Supply4. Connect three of the power supply cables to the mother

Page 106 - B.3 Updating SP Firmware

Chapter 4 Maintaining the Sun Fire X2250 Server 4-257. Replace the air duct. See Section 4.5.6.2, “Installing the Air Duct” on page 4-21.8. Check the

Page 107 - B.3.2 ILOM Web Interface

4-26 Sun Fire X2250 Server Service Manual • April 20094.5.8.2 Installing the Fan ModuleTo install the system fan module:1. Position the fan so that th

Page 108

Chapter 4 Maintaining the Sun Fire X2250 Server 4-271. Power off the system and remove the cover as described in Section 4.3,“Powering Off the Server

Page 109 - PXE Server

4-28 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-25 Installing the Dual Blower Module2. Gently push the blower module down, until you he

Page 110 - # cd /syslinux-3.09/memdisk

Chapter 4 Maintaining the Sun Fire X2250 Server 4-29 DIMM pairs must be populated in the following DIMM slot order: A0 & B0, C0 &D0, A1 &

Page 111

4-30 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-27 Bank 1 DIMM Slot Locations3. Remove a DIMM by pressing down on the ejector levers at

Page 112 - Sun Fire X2250 Server

Chapter 4 Maintaining the Sun Fire X2250 Server 4-31FIGURE 4-28 Removing a DIMM4.5.10.3 Installing a DIMMTo install a DIMM:1. Refer to Section 4.5.10.

Page 113 - Mainboard is Replaced

viii Sun Fire X2250 Server Service Manual • February 2010Index Index–1

Page 114

4-32 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-29 Installing a DIMM4. Using both thumbs, press the DIMM straight down into the DIMM sl

Page 115 - With Optional Slide Rails

Chapter 4 Maintaining the Sun Fire X2250 Server 4-334.5.11 Replacing the System BatteryThe system battery is a common CR2032 calculator battery.You mi

Page 116 - Installation

4-34 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-30 Removing the System BatteryCaution – Do not dispose of the battery with regular wast

Page 117 - FIGURE C-2.)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-354.5.11.2 Installing the System BatteryTo install the system battery:1. Insert the new system batte

Page 118 - FIGURE C-3.)

4-36 Sun Fire X2250 Server Service Manual • April 20094.5.12 Replacing a CPU and HeatsinkThe following procedure describes how to replace a CPU. The S

Page 119 - FIGURE C-4.)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-37FIGURE 4-32 Removing a HeatsinkCaution – The heatsink can become extremely hot. Be sure it has had

Page 120 - Rail-width spacer

4-38 Sun Fire X2250 Server Service Manual • April 2009FIGURE 4-33 Removing the CPU8. Lift the CPU out of the socket, leaving the release lever in the

Page 121 - Assemblies

Chapter 4 Maintaining the Sun Fire X2250 Server 4-393. Align the small triangle, on the upper left corner of the CPU, with the triangleon the corner o

Page 122 - FIGURE C-6.) Continue

4-40 Sun Fire X2250 Server Service Manual • April 20097. Use the entire syringe contents to apply thermal grease in a circular pattern tothe top of th

Page 123 - Assembly

Chapter 4 Maintaining the Sun Fire X2250 Server 4-41FIGURE 4-35 Installing the Heatsink13. Reinstall the cover.4.5.13 Installing a New CPUNote – Repla

Page 124 - Left slide-rail

ixPrefaceThe Sun Fire X2250 Server Service Manual provides a detailed description of thehardware and software applications that support the Sun Fire™

Page 125 - Left slide rail

4-42 Sun Fire X2250 Server Service Manual • April 20093. Ensure that the socket release lever is in the fully open, perpendicular positionand the CPU

Page 126 - CMA mounting

Chapter 4 Maintaining the Sun Fire X2250 Server 4-437. Rotate the socket release lever down until it snaps into place, securing the CPUin the socket.8

Page 127 - Right slide

4-44 Sun Fire X2250 Server Service Manual • April 20094.5.14 Replacing CablesFIGURE 4-38 shows the routing of the cables and motherboard connector loc

Page 128 - (on left slide rail)

Chapter 4 Maintaining the Sun Fire X2250 Server 4-45TABLE 4-3 describes the motherboard cable connections.4.5.15 MotherboardThe following procedures d

Page 129 - CMA cable hanger

4-46 Sun Fire X2250 Server Service Manual • April 20096. Using a 5-mm nut driver, remove the screws attaching the serial connector to thechassis.FIGUR

Page 130

Chapter 4 Maintaining the Sun Fire X2250 Server 4-471. Center the motherboard on the chassis so that the screw holes in themotherboard align with the

Page 131

4-48 Sun Fire X2250 Server Service Manual • April 20096. Reconnect all internal system cables.See Section 4.5.14, “Replacing Cables” on page 4-45.7. R

Page 132

Chapter 4 Maintaining the Sun Fire X2250 Server 4-49

Page 133

4-50 Sun Fire X2250 Server Service Manual • April 2009

Page 134

A-1APPENDIXASystem SpecificationsThis Appendix contains the following specifications for the Sun Fire X2250 server. Section A.1, “Physical Specificat