Sun-microsystems Sun StorEdge A3500 Manuel d'utilisateur Page 33

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 32
Chapter 2 StorEdge A3500 Configurations 2-17
2.4 2x7 Cabling
2.4.1 SCSI Cabling
2.4.1.1 Cable Lengths
The following tables show the lengths of each SCSI cable connected to the drive
connections on the respective controller modules.
The inboard IN/OUT connectors on each of the top four disk arrays are connected
together using a 0.2m SCSI jumper cable, part number 530-1883-xx.
The inboard IN/OUT connectors on the bottom three disk arrays are terminated
with differential SCSI terminators, part number 150-1890-xx.
TABLE 2-7 Controller Module A (2x7)
SCSI Port Number Cable Length Part Number
1 .8m 530-1884-xx
2 .8m 530-1884-xx
3 .8m 530-1884-xx
4 2m 530-1885-xx
5 2m 530-1885-xx
TABLE 2-8 Controller Module B (2x7)
SCSI Port Number Cable Length Part Number
1 2m 530-1885-xx
2 .8m 530-1884-xx
3 .8m 530-1884-xx
4 2m 530-1885-xx
5 2m 530-1885-xx
Vue de la page 32