Chapter 2 Installing the Rear-Access Adapter 19
10. Locate the hot-swap LED on the front card to determine if the card has been
activated and is attached to the system (see
FIGURE 2-11).
FIGURE 2-11 Location of the Rear-Access Adapter’s Hot-Swap LED on the Front Card
The hot-swap LED shows whether the adapter has been activated.
If the hot-swap LED is OFF (unlit), the I/O slots in the server have been set to full
hot swap and the adapter has been activated. Go to Step 15.
If the hot-swap LED is ON, then the I/O slots in the server have been set to basic
hot swap. You must use software commands to activate the I/O card. Go to
Step 11.
Note You should also use the hot-swap LEDs on the server when installing the
adapter. For example, Netra ct servers contain an OK to Remove LED ( ) on the
system status panel that is used like the hot-swap LED on this adapter. Refer to your
system’s service manual for a description on how the hot-swap LEDs are used
during a hot-swap installation.
11. Remove the wrist strap from the chassis and from your wrist.