Chapter 2 Hardware Installation and Removal 21
b. Press the latch on both ejector levers inward at the same time.
c. Swing out the ejector levers to their fully open position.
d. Slide the NEM out of its slot.
Support the weight of the NEM with one hand at the bottom of the NEM.
To Replace the ID Chip
1. After you have removed the failed NEM from the chassis, locate the ID chip at
the back of the board (see
FIGURE 2-6).
FIGURE 2-6 Location of ID Chip
2. Grasp the edges of the ID chip and pull straight up to remove it from the
board.
3. Remove the ID chip from the new NEM, and install it onto the failed board
that you will be returning to Sun.
4. Install the ID chip onto the new board (see
FIGURE 2-7).