Sun-microsystems Sun StorEdge A3500FC Manuel d'utilisateur Page 42

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 62
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 41
3-10 Sun StorEdge A3500/A3500FC Hardware Configuration Guide December 1999
In this configuration (from the front of the expansion cabinet), the following occurs:
Controller module A controls disk arrays 1 and 2 in the 2x7 cabinet and disk
arrays 1 through 3 in the 1x8 cabinet (
FIGURE 3-19).
Controller module B controls disk arrays 3 through 7 in the 2x7 cabinet
(
FIGURE 3-20).
Controller module C controls disk arrays 4 through 8 in the 1x8 cabinet
(
FIGURE 3-21).
3.1.4.3 SCSI Jumper Cables and Terminators
All StorEdge D1000 disk arrays in this configuration should have SCSI jumper cables
between the middle SCSI connectors (IN/OUT-1 and IN/OUT-2) and a differential
SCSI terminator in the far right SCSI connector (IN/OUT-2).
Vue de la page 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 61 62

Commentaires sur ces manuels

Pas de commentaire