Vue de la page 127
9-4 Sun Fire V120 and Netra 120 Server User’s Guide December 2001
To check the status of the supply rails and internal circuit breakers, type:
9.1.5 Checking the Internal Temperature (lom -t)
To check the internal temperature of the system and also the system’s warning and
shutdown threshold temperatures, type:
# lom -v
Supply voltages:
1 5V status=ok
2 3V3 status=ok
3 +12V status=ok
4 -12V status=ok
5 VDD status=ok
6 +3VSB status=ok
7 BATTERY status=ok
System status flags (circuit breakers):
1 SCSIA TERM status=ok
2 USB status=ok
3 SCC status=ok
# lom -t
System Temperature Sensors:
1 enclosure 25 degC : warning 67 degC : shutdown 72 degC
System Over-temperature Sensors:
1 cpu status=ok
#
Vue de la page 127