6.4.2 What to Do
1. Position the fan tray approximately 2 inches (5 centimeters) over its final
location in the system chassis.
2. Route the UltraSCSI disk data cable flat under the tab on the side of the fan
tray assembly.
3. Route the main power and keyswitch/power button/LED cables under the right
notch on the fan tray assembly.
For information about cable locations, see Section 5.5 “How to Connect the
System Cables” on page 155.
4. Route the I/O power cableunder the left notch on the fan tray assembly.
5. Lower the fan tray into place in the system chassis.
Align the tabs on the fan tray assembly with the notches on the chassis. Make
sure that you keep the UltraSCSI data cable flat against the side of the fan tray
assembly.
166 Sun Enterprise 220R Server Service Manual January 2000, Revision A