18 Sun Blade X6270 Server Module Installation Guide December 2009
Install DIMMs
1. Remove the cover from the server.
See “Remove Cover From Server” on page 11.
2. Remove the DIMM filler panel.
See “Remove or Insert Filler Panels” on page 12.
3. To install a DIMM, do the following:
a. Determine the DIMM socket location to populate.
See “DIMM Population Rules” on page 16.
b. Ensure that the DIMM ejector levers are open (angled outward).
See ejector lever position in
FIGURE 2-4.
c. Align the DIMM notch to the DIMM connector key.
d. Using both thumbs, press the DIMM straight down into the DIMM
connector slot until both ejector levers close, locking the DIMM in the
socket.
Note The DIMM must be inserted evenly, straight down into the DIMM connector
slot, until the ejector levers lock into place.
TABLE 2-3 DIMM Classification Labels
Rank Classification Label
Quad-rank DIMM 4Rx4
Dual-rank DIMM 2Rx4
Single-rank DIMM 1Rx4